Customization: | Available |
---|---|
Certification: | CE, ISO |
Installation Method: |
Vertical |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High - Efficiency Filtration
These state-of-the-art dust collectors boast an exceptional high-efficiency filtration system. They expertly capture a broad spectrum of particulate matter, from the finest specks of dust to more substantial particulates and fume during the highly intricate laser-cutting processes. With a filtration efficiency that often soars to a remarkable 99.99% or even higher, these systems ensure that the air released from them is pure and devoid of any harmful particles.
Adaptability to Different Dust Types
Laser cutting operations generate a diverse array of dust types, contingent upon the materials being processed. The dust collectors are ingeniously designed to manage varying dust characteristics with ease. When dealing with metal cutting, they proficiently handle metal fines and fume, and when processing plastics or composites, they seamlessly adapt to the specific dust properties of these materials.
Powerful Suction Capacity
With impressive power and efficiency, these dust collectors boast a formidable suction capacity to swiftly remove dust from the cutting vicinity. The potent suction force captures dust instantly as it forms, preventing dispersion within the workshop. This is vital for preserving a pristine and secure working environment and safeguarding the delicate components of the laser cutting machine from potential dust-induced damage.
Compact and Space - Saving Design
Ingeniously crafted, many of these dust collectors feature a compact design. They are effortlessly installed adjacent to the laser-cutting machine without encroaching on precious floor space. Their space-efficient design optimizes workshop layout and ensures seamless connection to cutting equipment for highly efficient dust collection.
Low Noise Operation
Expertly engineered, the dust collectors operate with a remarkably low noise output. This significantly enhances the work environment by minimizing noise pollution. Their noise levels are meticulously controlled, typically staying below 80 decibels, allowing workers to maintain focus without disruption from the dust-collecting equipment.
Safe and Reliable Operation
These dust collectors are outfitted with advanced safety features such as over-temperature and over-current protection. These features guarantee the equipment operates safely and reliably. In the event of unusual conditions, these safety measures are triggered to avert damage to the dust collector and associated equipment, ensuring operator safety is uncompromised.
Model | Airflow m3/h |
Power kW |
Voltage V |
Filter Area m2 |
Filter Precision % |
Noise dB(A) |
Size mm |
HXHJ-XF04 | 4000 | 5.5KW | 380V/50Hz/3P 415V/50Hz/3P 220V/60Hz/3p |
52 | 99.99% | 77±3 | 1200*1100*2500 |
HXHJ-XF06 | 6000 | 7.5kW | 78 | 99.99% | 77±3 | 1200*1400*2500 | |
HXHJ-XF09 | 9000 | 11kW | 117 | 99.99% | 77±3 | 1600*1400*2500 | |
HXHJ-XF12 | 12000 | 15kW | 156 | 99.99% | 77±3 | 1600*1700*2500 | |
HXHJ-XF16 | 16000 | 18.5Kw | Same | 208 | 99.99% | 77±3 | 2000*1700*2700 |
HXHJ-XF20 | 20000 | 22kW | Same | 260 | 99.99% | 77±3 | 2100*2200*2800 |
Q1: Is there any noise?
A 1: The fans will have sound insulation cotton and will not produce excessive noise.
Q2: Why is the plastic spraying process recommended for the surface treatment of the dust colector?
A 2: The paint is not easy to fal off , and it is more durable.
Q3: How to configure the air volume of the dust colector?
A 3: There is an exhaust port at the botom of the cutting platform, which is already standard when the laser cutting machine leaves the factory. You only need to measure the diameter of the pipe , and then tel us, by calculation, you can know how much air volume is needed for the dust collector .
Q4: Alot of sparks wil be generated during cutting, which may scald the filter material of the dust collector or burn the filter material directly, causing a fire accident . How to avoid such accidents?
A4 : Install spark catcher. There are three types of spark traps, embedded baffle type, pipe baffle type, and pipe swirl type.The spark catcher uses a labyrinth structure to make the spark enter the cold plate several times to extinguish it .
Q5: The dust and fume generated during cutting will polute the air in the workshop .How to eliminate such pollution?
A5 : The high - precision imported flame-retardant filter material is used as the standard filter cartridge filter unit to filter dust and smoke, similar to the filter element of an automobile engine .
Q6: Do you need to vent a chimney?
A 6: No need to discharge the chimney. High-precision filter material is used to filter 0.3Um dust , with a dust removal efficiency of over 99%, and it can be directly discharged indoors .
Q7: Can the environmental protection meet the standards?
A7: It can meet the standard.