Customization: | Available |
---|---|
Certification: | CE, ISO |
Installation Method: |
Vertical |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High - Efficiency Filtration
These cutting-edge dust collectors are meticulously engineered with an advanced, high-efficiency filtration system. They are adept at capturing a diverse array of particulate matter, from the finest dust to more substantial particles and fume generated during the laser-cutting process. The remarkable filtration efficiency often reaches an astounding 99.99% or even higher, ensuring the air released is exceptionally clean, safeguarding your workspace from harmful particles.
Adaptability to Different Dust Types
Laser cutting operations can produce an assortment of dust types, contingent on the materials processed. Our dust collectors are expertly designed to handle varied dust characteristics. For instance, when processing metal, they efficiently manage metal fines and fume; likewise, when working with plastics or composites, they adeptly adjust to the distinct properties of those materials' dust.
Powerful Suction Capacity
Our dust collectors boast a formidable suction capacity to swiftly and efficiently extract dust from the cutting area. The potent suction force captures dust immediately upon generation, preventing dispersion across the workshop. This is pivotal for preserving a spotless, safe working environment and for safeguarding the delicate components of your laser cutting machine from potential dust damage.
Compact and Space - Saving Design
Ingeniously designed, these dust collectors are exceedingly compact, facilitating easy installation near your laser-cutting machine without monopolizing precious floor space. Their space-conscious design maximizes workshop area utility and permits seamless connection to cutting equipment for optimal dust collection efficiency.
Low Noise Operation
Our dust collectors are crafted to operate within a relatively low noise spectrum, significantly enhancing the working environment by minimizing noise pollution. Their operational noise is meticulously maintained within acceptable limits, typically below 80 decibels, ensuring that workers can maintain concentration on their tasks, undisturbed by intrusive noise from the dust-collecting apparatus.
Safe and Reliable Operation
Equipped with robust safety features such as over-temperature protection and over-current protection, these dust collectors guarantee safe, reliable operation. In the event of any anomalies, these safety mechanisms activate to avert damage to the dust collector and affiliated equipment, ensuring the utmost safety for operators.
Model | Airflow m3/h |
Power kW |
Voltage V |
Filter Area m2 |
Filter Precision % |
Noise dB(A) |
Size mm |
HXHJ-XF04 | 4000 | 5.5KW | 380V/50Hz/3P 415V/50Hz/3P 220V/60Hz/3p |
52 | 99.99% | 77±3 | 1200*1100*2500 |
HXHJ-XF06 | 6000 | 7.5kW | 78 | 99.99% | 77±3 | 1200*1400*2500 | |
HXHJ-XF09 | 9000 | 11kW | 117 | 99.99% | 77±3 | 1600*1400*2500 | |
HXHJ-XF12 | 12000 | 15kW | 156 | 99.99% | 77±3 | 1600*1700*2500 | |
HXHJ-XF16 | 16000 | 18.5Kw | Same | 208 | 99.99% | 77±3 | 2000*1700*2700 |
HXHJ-XF20 | 20000 | 22kW | Same | 260 | 99.99% | 77±3 | 2100*2200*2800 |
Q1: Is there any noise?
A 1: The fans will have sound insulation cotton and will not produce excessive noise.
Q2: Why is the plastic spraying process recommended for the surface treatment of the dust colector?
A 2: The paint is not easy to fal off , and it is more durable.
Q3: How to configure the air volume of the dust colector?
A 3: There is an exhaust port at the botom of the cutting platform, which is already standard when the laser cutting machine leaves the factory. You only need to measure the diameter of the pipe , and then tel us, by calculation, you can know how much air volume is needed for the dust collector .
Q4: Alot of sparks wil be generated during cutting, which may scald the filter material of the dust collector or burn the filter material directly, causing a fire accident . How to avoid such accidents?
A4 : Install spark catcher. There are three types of spark traps, embedded baffle type, pipe baffle type, and pipe swirl type.The spark catcher uses a labyrinth structure to make the spark enter the cold plate several times to extinguish it .
Q5: The dust and fume generated during cutting will polute the air in the workshop .How to eliminate such pollution?
A5 : The high - precision imported flame-retardant filter material is used as the standard filter cartridge filter unit to filter dust and smoke, similar to the filter element of an automobile engine .
Q6: Do you need to vent a chimney?
A 6: No need to discharge the chimney. High-precision filter material is used to filter 0.3Um dust , with a dust removal efficiency of over 99%, and it can be directly discharged indoors .
Q7: Can the environmental protection meet the standards?
A7: It can meet the standard.