Customization: | Available |
---|---|
Certification: | CE, ISO |
Installation Method: |
Vertical |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
High - Efficiency Filtration
These dust collectors boast a state-of-the-art high-efficiency filtration system, expertly engineered to capture a wide spectrum of particulate matter, including the most elusive fine dust and fume emitted during the laser - cutting process. With a filtration efficiency often reaching an astounding 99.99% or even higher, you can rest assured that the air discharged from the system is impeccably clean, free from harmful particles.
Adaptability to Different Dust Types
Laser cutting operations unearth various types of dust, contingent on the materials being processed. The dust collectors are ingeniously crafted to tackle diverse dust characteristics. For instance, when cutting metal, the dust collector deftly manages metal fines and fume, while cutting plastics or composites, it seamlessly adapts to the distinct properties of those materials' dust.
Powerful Suction Capacity
Engineered with a robust suction capacity, these dust collectors swiftly and efficiently extract dust from the cutting area. The potent suction force ensures immediate capture of dust upon production, averting its dissemination across the workshop. This is vital for preserving a pristine, safe working environment and safeguarding the precision components of the laser cutting machine from detrimental dust exposure.
Compact and Space - Saving Design
These dust collectors are innovatively designed to be compact, facilitating effortless installation near the laser - cutting machine without occupying excessive valuable floor space. Their space - conserving design promotes optimal workshop area utilization and allows for effortless connection to cutting equipment for proficient dust collection.
Low Noise Operation
Engineered for minimal noise output, these dust collectors are a boon to the working environment, significantly curtailing noise pollution. The noise level consistently maintains an agreeable range, typically beneath 80 decibels, ensuring workers can maintain focus on their tasks without the distraction of excessive noise from dust - collecting equipment.
Safe and Reliable Operation
Safety is paramount; hence, these dust collectors are fortified with advanced safety features such as over-temperature protection and over - current protection. These elements are vital for the secure and reliable operation of the equipment. Should abnormal conditions arise, the safety mechanisms promptly activate to avert damage to the dust collector and associated apparatus, ensuring operator safety.
Model | Airflow m3/h |
Power kW |
Voltage V |
Filter Area m2 |
Filter Precision % |
Noise dB(A) |
Size mm |
HXHJ-XF04 | 4000 | 5.5KW | 380V/50Hz/3P 415V/50Hz/3P 220V/60Hz/3p |
52 | 99.99% | 77±3 | 1200*1100*2500 |
HXHJ-XF06 | 6000 | 7.5kW | 78 | 99.99% | 77±3 | 1200*1400*2500 | |
HXHJ-XF09 | 9000 | 11kW | 117 | 99.99% | 77±3 | 1600*1400*2500 | |
HXHJ-XF12 | 12000 | 15kW | 156 | 99.99% | 77±3 | 1600*1700*2500 | |
HXHJ-XF16 | 16000 | 18.5Kw | Same | 208 | 99.99% | 77±3 | 2000*1700*2700 |
HXHJ-XF20 | 20000 | 22kW | Same | 260 | 99.99% | 77±3 | 2100*2200*2800 |
Q1: Is there any noise?
A 1: The fans will have sound insulation cotton and will not produce excessive noise.
Q2: Why is the plastic spraying process recommended for the surface treatment of the dust colector?
A 2: The paint is not easy to fal off , and it is more durable.
Q3: How to configure the air volume of the dust colector?
A 3: There is an exhaust port at the botom of the cutting platform, which is already standard when the laser cutting machine leaves the factory. You only need to measure the diameter of the pipe , and then tel us, by calculation, you can know how much air volume is needed for the dust collector .
Q4: Alot of sparks wil be generated during cutting, which may scald the filter material of the dust collector or burn the filter material directly, causing a fire accident . How to avoid such accidents?
A4 : Install spark catcher. There are three types of spark traps, embedded baffle type, pipe baffle type, and pipe swirl type.The spark catcher uses a labyrinth structure to make the spark enter the cold plate several times to extinguish it .
Q5: The dust and fume generated during cutting will polute the air in the workshop .How to eliminate such pollution?
A5 : The high - precision imported flame-retardant filter material is used as the standard filter cartridge filter unit to filter dust and smoke, similar to the filter element of an automobile engine .
Q6: Do you need to vent a chimney?
A 6: No need to discharge the chimney. High-precision filter material is used to filter 0.3Um dust , with a dust removal efficiency of over 99%, and it can be directly discharged indoors .
Q7: Can the environmental protection meet the standards?
A7: It can meet the standard.